HEWLETT-PACKARD COMPANY
HP C1539
Device Type |
Internal Tape Drive |
Interface |
SCSI-2 |
Format |
DDS, DDS-2, DDS-DC |
Sustained Transfer Rate |
510 KBPS (native), 1 KBPS/1.5 KBPS (compressed) |
Size |
3.5 in. half height |
View |
Top |
USER CONFIGURABLE SETTINGS | |||
Setting |
Label |
Position | |
Factory configured - do not alter |
JP5 |
Unidentified | |
Media Recognition System enabled |
SW1/3 |
Off | |
Media Recognition System disabled |
SW1/3 |
On | |
Factory configured - do not alter |
SW1/4 |
On | |
Factory configured - do not alter |
SW1/5 |
On | |
Factory configured - do not alter |
SW1/6 |
On | |
Factory configured - do not alter |
SW1/7 |
On | |
Factory configured - do not alter |
SW1/8 |
On |
DATA COMPRESSION SETTINGS | |||
Function |
SW1/1 |
SW1/2 | |
Data compression enabled managed by system |
On |
On | |
Data compression disabled |
Off |
Off | |
Data compression disabled managed by system |
Off |
On | |
Data compression enabled not managed by system |
On |
Off |
DRIVE SELECT ID | |||
Drive ID |
JP2 |
JP3 |
JP4 |
0 |
Open |
Open |
Open |
1 |
Open |
Open |
Closed |
2 |
Open |
Closed |
Open |
3 |
Open |
Closed |
Closed |
4 |
Closed |
Open |
Open |
5 |
Closed |
Open |
Closed |
6 |
Closed |
Closed |
Open |
7 |
Closed |
Closed |
Closed |
TERMINATION POWER SELECTION | ||
Setting |
JP1 | |
TERMPWR supplied by drive to SCSI interface |
Open | |
TERMPWR supplied by drive |
Closed |
MANUFACTURERS RECOMMENDED MEDIA | ||
Tape |
Capacity Without Compression |
Capacity With Compression |
60 meter DDS cartridge |
1.3GB |
2.6GB |
90 meter DDS cartridge |
2.0GB |
4.0GB |
120 meter DDS cartridge |
4.0GB |
8.0/16.0GB |
Note: Maximum capacity is dependent on data type. |
DIAGNOSTIC LED(S) | |||
LED |
Color |
Status |
Condition |
LED1 |
Green |
On |
Cartridge present, drive active |
LED1 |
Green |
Slow Blinking |
Cartridge loading or unloading |
LED1 |
Green |
Fast Blinking |
Cartridge is being read or written to |
LED1 |
Green |
Off |
No power/drive Idle, no cartridge |
LED2 |
Yellow |
On |
Drive fault detected |
LED2 |
Yellow |
Blinking |
Drive cleaning required |
LED2 |
Yellow |
Off |
No drive fault detected |