HEWLETT-PACKARD COMPANY
HP C1599A
Device Type |
Internal Tape Drive |
Interface |
SCSI-2 |
Format |
DDS-DC, DDS-2 |
Sustained Transfer Rate |
510 KBPS 1.0 MBPS (with compression) |
Size |
3.5 in. half height |
View |
Top |
USER CONFIGURABLE SETTINGS | |||
Setting |
Label |
Position | |
Factory configured - do not alter |
JP5 |
Unidentified | |
Note: Jumper JP5 causes data compression on writes to be disabled at power on if connected to ground. A host may override this unless "switch 2" on underside of drive is set to OFF. Exact location and orientation of "switch 2" is unidentified. |
DRIVE SELECT ID | |||
Drive ID |
JP1 |
JP2 |
JP3 |
0 |
Open |
Open |
Open |
1 |
Open |
Open |
Closed |
2 |
Open |
Closed |
Open |
3 |
Open |
Closed |
Closed |
4 |
Closed |
Open |
Open |
5 |
Closed |
Open |
Closed |
6 |
Closed |
Closed |
Open |
7 |
Closed |
Closed |
Closed |
MANUFACTURERS RECOMMENDED MEDIA | ||
Tape |
Capacity Without Compression |
Capacity With Compression |
60 meter DDS cartridge |
1.3 GB |
2.6 GB |
90 meter DDS cartridge |
2.0 GB |
4.0 GB |
120 meter DDS-2 cartridge |
4.0 GB |
8.0 GB |
DIAGNOSTIC LED(S) | ||
LED1 (Green) |
LED2 (Yellow) |
Condition |
Off |
Off |
No power/drive Idle, no cartridge |
On |
Off |
Cartridge loaded, No Activity |
Flash |
Off |
Cartridge loaded, Activity |
Pulse |
Off |
Loading/Unloading/Ejecting/Power-On |
Off |
On |
Self Test Failure |
Off |
Pulse |
No Cartridge, Caution (cleaning required) |
On |
Pulse |
Cartridge loaded, Caution (cleaning required) |
Flash |
Pulse |
Cartridge loaded, Drive Active, Caution (cleaning required) |
Pulse |
Pulse |
Cartridge loading/unloading, Caution (cleaning required) |