THOMAS-CONRAD CORPORATION
TC3042-ST (Version 1.0) TCNS 8-BIT
NIC Type |
TCNS (Proprietary) |
Transfer Rate |
100Mbps |
Data Bus |
8-bit ISA |
Topology |
Star |
Wiring Type |
Fiber optic cable |
Boot ROM |
Available |
BASE I/O ADDRESS | |||||||
Address |
SW3/1 |
SW3/2 |
SW3/3 |
SW3/4 |
SW3/5 |
SW3/6 | |
2E0h |
Off |
On |
Off |
Off |
Off |
On | |
2F0h |
Off |
On |
Off |
Off |
Off |
Off | |
300h |
Off |
Off |
On |
On |
On |
On | |
350h |
Off |
Off |
On |
Off |
On |
Off |
BASE MEMORY ADDRESS | |||||||||
Address |
SW1/1 |
SW1/2 |
SW1/3 |
SW1/4 |
SW1/5 |
SW1/6 |
SW1/7 |
SW1/8 | |
D000h |
Off |
Off |
On |
Off |
On |
On |
On |
On | |
C000h |
Off |
Off |
On |
On |
On |
On |
On |
On | |
C400h |
Off |
Off |
On |
On |
On |
Off |
On |
On | |
C800h |
Off |
Off |
On |
On |
Off |
On |
On |
On | |
CC00h |
Off |
Off |
On |
On |
Off |
Off |
On |
On | |
D400h |
Off |
Off |
On |
Off |
On |
Off |
On |
On | |
D800h |
Off |
Off |
On |
Off |
Off |
On |
On |
On | |
DC00h |
Off |
Off |
On |
Off |
Off |
Off |
On |
On | |
E000h |
Off |
Off |
Off |
On |
On |
On |
On |
On |
DIAGNOSTIC LED(S) | |||
LED |
Color |
Status |
Condition |
LED1 |
Red |
On |
Data is being transmitted or received. |
LED1 |
Red |
Blinking |
Network connection is bad |
LED1 |
Red |
Off |
No network connection, or the card is malfunctioning. |
FACTORY CONFIGURED SETTINGS | |
Switch |
Setting |
SW3/switch 8 |
N/A |
INTERRUPT SETTINGS | |||||||
IRQ |
JP6B |
JP6C |
JP6D |
JP6E |
JP6F |
JP6G | |
2 |
Closed |
Open |
Open |
Open |
Open |
Open | |
3 |
Open |
Closed |
Open |
Open |
Open |
Open | |
4 |
Open |
Open |
Closed |
Open |
Open |
Open | |
5 |
Open |
Open |
Open |
Closed |
Open |
Open | |
6 |
Open |
Open |
Open |
Open |
Closed |
Open | |
7 |
Open |
Open |
Open |
Open |
Open |
Closed |
NODE ADDRESS | ||||||||||
Node |
SW2/1 |
SW2/2 |
SW2/3 |
SW2/4 |
SW2/5 |
SW2/6 |
SW2/7 |
SW2/8 | ||
0 |
- |
- |
- |
- |
- |
- |
- |
- | ||
1 |
Off |
On |
On |
On |
On |
On |
On |
On | ||
2 |
On |
Off |
On |
On |
On |
On |
On |
On | ||
3 |
Off |
Off |
On |
On |
On |
On |
On |
On | ||
4 |
On |
On |
Off |
On |
On |
On |
On |
On | ||
251 |
Off |
Off |
On |
Off |
Off |
Off |
Off |
Off | ||
252 |
On |
On |
Off |
Off |
Off |
Off |
Off |
Off | ||
253 |
Off |
On |
Off |
Off |
Off |
Off |
Off |
Off | ||
254 |
On |
Off |
Off |
Off |
Off |
Off |
Off |
Off | ||
255 |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
Off | ||
Notes: Node address 0 is used for messaging between nodes and must not be used. A total of 255 node address settings are available. The switches are a binary representation of the decimal node addresses. Switch 1 is the Least Significant Bit and switch 8 is the Most Significant Bit. The switches have the following decimal values: switch 1=1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128. Turn off the switches and add the values of the off switches to obtain the correct node address. (On=0, off=1) |
OPERATING MODE | ||
Mode |
SW3/switch 7 | |
Enhanced Mode |
On | |
Compatible Mode |
Off |
WAIT STATE CONFIGURATION | ||
0 Wait State |
JP1 | |
Disabled |
Open | |
Enabled |
Closed |