PURE DATA, LTD.
PDI7023-16CAT
NIC Type |
Ethernet |
Transfer Rate |
10Mbps |
Data Bus |
16-bit ISA |
Topology |
Star Linear bus |
Wiring Type |
Unshielded twisted pair RG58A/U 50ohm coaxial AUI transceiver via DB-15 port |
Boot ROM |
Not available |
COAXIAL SEGMENT LENGTH | ||
Maximum Length |
E1 | |
200 meters |
Closed | |
300 meters |
Open |
INTERRUPT REQUEST | |||||||||||
IRQ |
E2A |
E2B |
E2C |
E2D |
E2E |
E2F |
E2G |
E2H |
E2I |
E2J | |
2/9 |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open | |
3 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed | |
4 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open | |
5 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open | |
6 |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open | |
7 |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open | |
10 |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open | |
11 |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open | |
12 |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open | |
15 |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
CABLE TYPE | ||
Type |
Isolation Transformer Location | |
Unshielded twisted pair |
N/A | |
RG58A/U 50ohm coaxial |
T2 | |
AUI transceiver via DB-15 port |
T3 | |
Note:The cable type is automatically selected, but the isolation transformer must be moved to the proper socket to enable the BNC connector or DB-15 port.
|
I/O BASE ADDRESS | ||||
Address |
SW1/1 |
SW1/2 |
SW1/3 | |
260h |
On |
On |
On | |
290h |
Off |
On |
On | |
2E0h |
On |
Off |
On | |
2F0h |
Off |
Off |
On | |
300h |
On |
On |
Off | |
350h |
Off |
On |
Off | |
380h |
On |
Off |
Off | |
3E0h |
Off |
Off |
Off |
EXTENDED TRANSMIT TIMEOUT | ||
Setting |
SW1/5 | |
Enabled |
On | |
Disabled |
Off | |
Note:With this option enabled, if the card is transmitting for an extended amount of time the transmission will be interrupted and continued after a preset time. This keeps one card from dominating the network. |
LINK INTEGRITY TEST | ||
Setting |
SW1/7 | |
Enabled |
On | |
Disabled |
Off | |
Note:The link integrity test is valid only when the cable type is unshielded twisted pair. |
FACTORY CONFIGURED SETTINGS | |
Switch |
Setting |
SW1/4 |
Off |
SW1/6 |
On |
SW1/8 |
Off |
DIAGNOSTIC LED(S) | |||
LED |
Color |
Status |
Condition |
LED1 |
Green |
On |
Data is being transmitted or received |
LED1 |
Green |
Off |
Data is not being transmitted or received |
LED2 |
Red |
On |
Card is being accessed by host computer |
LED2 |
Red |
Off |
Card is not being accessed by host computer |
LED3 |
Red |
On |
Collision detected on network |
LED3 |
Red |
Off |
Normal operation |
LED4 |
Green |
On |
Cable type is AUI via DB-15 or RG-58A/U coaxial |
LED4 |
Green |
Off |
Cable type is Twisted pair |