IPTool.net.ua IPTools.net.ua

PDI7023-16CAT

PURE DATA, LTD.

PDI7023-16CAT

NIC Type

Ethernet

Transfer Rate

10Mbps

Data Bus

16-bit ISA

Topology

Star

Linear bus

Wiring Type

Unshielded twisted pair

RG58A/U 50ohm coaxial

AUI transceiver via DB-15 port

Boot ROM

Not available

COAXIAL SEGMENT LENGTH

Maximum Length

E1

200 meters

Closed

 

300 meters

Open

INTERRUPT REQUEST

IRQ

E2A

E2B

E2C

E2D

E2E

E2F

E2G

E2H

E2I

E2J

 

2/9

Open

Open

Open

Open

Closed

Open

Open

Open

Open

Open

 

3

Open

Open

Open

Open

Open

Open

Open

Open

Open

Closed

4

Open

Open

Open

Open

Open

Open

Open

Open

Closed

Open

 

5

Open

Open

Open

Open

Open

Open

Open

Closed

Open

Open

 

6

Open

Open

Open

Open

Open

Open

Closed

Open

Open

Open

 

7

Open

Open

Open

Open

Open

Closed

Open

Open

Open

Open

 

10

Open

Open

Open

Closed

Open

Open

Open

Open

Open

Open

 

11

Open

Open

Closed

Open

Open

Open

Open

Open

Open

Open

 

12

Open

Closed

Open

Open

Open

Open

Open

Open

Open

Open

 

15

Closed

Open

Open

Open

Open

Open

Open

Open

Open

Open

CABLE TYPE

Type

Isolation Transformer Location

Unshielded twisted pair

N/A

 

RG58A/U 50ohm coaxial

T2

 

AUI transceiver via DB-15 port

T3

Note:The cable type is automatically selected, but the isolation transformer must be moved to the proper socket to enable the BNC connector or DB-15 port.

I/O BASE ADDRESS

Address

SW1/1

SW1/2

SW1/3

 

260h

On

On

On

 

290h

Off

On

On

 

2E0h

On

Off

On

 

2F0h

Off

Off

On

300h

On

On

Off

 

350h

Off

On

Off

 

380h

On

Off

Off

 

3E0h

Off

Off

Off

EXTENDED TRANSMIT TIMEOUT

Setting

SW1/5

Enabled

On

 

Disabled

Off

Note:With this option enabled, if the card is transmitting for an extended amount of time the transmission will be interrupted and continued after a preset time. This keeps one card from dominating the network.

LINK INTEGRITY TEST

Setting

SW1/7

Enabled

On

 

Disabled

Off

Note:The link integrity test is valid only when the cable type is unshielded twisted pair.

FACTORY CONFIGURED SETTINGS

Switch

Setting

SW1/4

Off

SW1/6

On

SW1/8

Off

DIAGNOSTIC LED(S)

LED

Color

Status

Condition

LED1

Green

On

Data is being transmitted or received

LED1

Green

Off

Data is not being transmitted or received

LED2

Red

On

Card is being accessed by host computer

LED2

Red

Off

Card is not being accessed by host computer

LED3

Red

On

Collision detected on network

LED3

Red

Off

Normal operation

LED4

Green

On

Cable type is AUI via DB-15 or RG-58A/U coaxial

LED4

Green

Off

Cable type is Twisted pair