IPTool.net.ua IPTools.net.ua

PDI7023-16FL

PURE DATA, LTD.

PDI7023-16FL

NIC Type

Ethernet

Transfer Rate

10Mbps

Data Bus

16-bit ISA

Topology

Star

Wiring Type

62.5/125 m m Fiber optic cable (e.g. Belden 227412)

Boot ROM

Not available

INTERRUPT REQUEST

IRQ

E2A

E2B

E2C

E2D

E2E

E2F

E2G

E2H

E2I

E2J

 

2/9

Open

Open

Open

Open

Closed

Open

Open

Open

Open

Open

 

3

Open

Open

Open

Open

Open

Open

Open

Open

Open

Closed

4

Open

Open

Open

Open

Open

Open

Open

Open

Closed

Open

 

5

Open

Open

Open

Open

Open

Open

Open

Closed

Open

Open

 

6

Open

Open

Open

Open

Open

Open

Closed

Open

Open

Open

 

7

Open

Open

Open

Open

Open

Closed

Open

Open

Open

Open

 

10

Open

Open

Open

Closed

Open

Open

Open

Open

Open

Open

 

11

Open

Open

Closed

Open

Open

Open

Open

Open

Open

Open

 

12

Open

Closed

Open

Open

Open

Open

Open

Open

Open

Open

 

15

Closed

Open

Open

Open

Open

Open

Open

Open

Open

Open

LOOP BACK ENABLE

Setting

E7

Disabled

Pins 1 & 2 closed

 

Enabled

Pins 2 & 3 closed

Note:The loop back is used with diagnostic software to trouble-shoot the card.

I/O BASE ADDRESS

Address

SW1/1

SW1/2

SW1/3

 

260h

On

On

On

 

290h

Off

On

On

 

2E0h

On

Off

On

 

2F0h

Off

Off

On

300h

On

On

Off

 

350h

Off

On

Off

 

380h

On

Off

Off

 

3E0h

Off

Off

Off

JUMPER E6 ENABLE

Setting

SW1/5

Enabled

On

 

Disabled

Off

Note:If this option is disabled (SW1/5 Off) the options selected using E6 are disabled.

EXTENDED TRANSMIT TIMEOUT AND SIGNAL QUALITY ERROR (SQE) TEST

Timeout

SQE

E6A

E6B

E6C

Enabled

Enabled

Closed

Open

Open

Disabled

Disabled

Open

Closed

Open

Enabled

Disabled

Open

Open

Closed

Note:SW1/5 must be set to on for these settings to be valid.

With extended transmit timeout enabled, if the card is transmitting for an extented amount of time the transmission will be interrupted and continued after a preset time. This keeps the card from dominating the network.

Signal Quality Error (SQE) is a test of the collision circuitry and path.

E6A, E6B, and E6C are located on the PIM module.

LINK INTEGRITY TEST

Setting

SW1/7

Enabled

On

 

Disabled

Off

Note:E7 is located on the PIM module.

FACTORY CONFIGURED SETTINGS

Switch

Setting

SW1/4

Off

SW1/6

On

SW1/8

Off

DIAGNOSTIC LED(S)

LED

Color

Status

Condition

LED1

Green

On

Data is being transmitted

LED1

Green

Off

Data is not being transmitted

LED2

Amber

On

Data is being received

LED2

Amber

Off

Data is not being received

LED3

Amber

On

Network connection is good

LED3

Amber

Off

Network connection is broken

LED4

Red

On

Card is transmitting for an extended time

LED4

Red

Off

Normal operation

LED5

Red

On

Collision detected on network

LED5

Red

Off

Normal operation