LANTECH COMPUTER CORPORATION
EN2000/CT
NIC Type |
Ethernet |
Network Transfer Rate |
10Mbps |
Data Bus |
16-bit ISA |
Topology |
Linear Bus, Star |
Wiring Type |
Unshielded twisted pair RG-58A/U 50ohm coaxial |
Boot ROM |
Available |
CONNECTIONS | |||
Function |
Label |
Function |
Label |
Unshielded twisted pair port |
CN1 |
RG-58A/U 50ohm coaxial port |
CN2 |
CONFIGURATION SELECTION | ||
Setting |
JP2/A |
JP2/B |
Software configures I/O Base address, Boot ROM address and Interrupt |
Open |
Closed |
Hardware configures I/O Base address, Boot ROM address and Interrupt |
Closed |
Open |
Note: Jumpers JP1/C-JP1/J and JP2 must be set if hardware configuration is selected. If software configuration is selected JP1/A, JP1/C-J and JP2 should be open. |
BASE I/O ADDRESS SELECTION | |||
Address |
JP1/A |
JP1/B |
JP1/C |
300h |
Open |
Open |
Open |
320h |
Closed |
Open |
Open |
340h |
Open |
Closed |
Open |
360h |
Closed |
Closed |
Open |
200h |
Open |
Open |
Closed |
220h |
Closed |
Open |
Closed |
240h |
Open |
Closed |
Closed |
260h |
Closed |
Closed |
Closed |
BOOT ROM SELECTION | |||||
Size |
JP1/D |
JP1/E |
JP1/F |
JP1/G |
JP1/H |
Disabled |
N/A |
N/A |
N/A |
Open |
Open |
C000h, 16KB |
Open |
Open |
Open |
Open |
Closed |
C400h, 16KB |
Closed |
Open |
Open |
Open |
Closed |
C800h, 16KB |
Open |
Closed |
Open |
Open |
Closed |
CC00h, 16KB |
Closed |
Closed |
Open |
Open |
Closed |
D000h, 16KB |
Open |
Open |
Closed |
Open |
Closed |
D400h, 16KB |
Closed |
Open |
Closed |
Open |
Closed |
D800h, 16KB |
Open |
Closed |
Closed |
Open |
Closed |
DC00h, 16KB |
Closed |
Closed |
Closed |
Open |
Closed |
C000h, 32KB |
Open |
Open |
Open |
Closed |
Open |
C800h, 32KB |
Closed |
Open |
Open |
Closed |
Open |
D000h, 32KB |
Open |
Closed |
Open |
Closed |
Open |
D800h, 32KB |
Closed |
Closed |
Open |
Closed |
Open |
C000h, 64KB |
Open |
Open |
Closed |
Closed |
Open |
D000h, 64KB |
Closed |
Open |
Closed |
Closed |
Open |
INTERRUPT SELECTION | ||||||||
IRQ |
JP2/C |
JP2/D |
JP2/E |
JP2/F |
JP2/G |
JP2/H |
JP2/I |
JP2/J |
2/9 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
3 |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
4 |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
5 |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
10 |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
11 |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
12 |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
15 |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
DIAGNOSTIC LED(S) | ||
LED |
Status |
Condition |
LED1 |
On |
Data is being transmitted/received |
LED1 |
Off |
Data is not being transmitted/received |