GARRETT COMMUNICATIONS
MAGNUM TP1
Card Type |
Ethernet Transceiver |
NIC Type |
Ethernet |
Maximum Onboard Memory |
Unidentified |
Boot ROM |
Not available |
Network Transfer Rate |
10Mbps |
Topology |
Linear Bus, Star |
Wiring Type |
Shielded twisted pair, Unshielded twisted pair AUI transceiver via DB-15 port |
Data Bus |
External |
CONNECTIONS | |||
Function |
Label |
Function |
Label |
AUI transceiver via DB-15 |
CN1 |
UTP/STP connector (RJ-45) |
CN2 |
USER CONFIGURABLE SETTINGS | |||
Function |
Label |
Position | |
Automatic correction for reversed polarity enabled |
SW1 |
On | |
Automatic correction for reversed polarity disabled |
SW1 |
Off | |
Unshielded twisted pair |
SW2 |
Off | |
Shielded twisted pair |
SW2 |
On | |
10BASE-T enabled |
SW3 |
On | |
Starlan 10 (ATT) polarity on the segment |
SW3 |
Off | |
SQE enabled |
SW4 |
On | |
SQE disabled |
SW4 |
Off |
DIAGNOSTIC LED(S) | |||
LED |
Color |
Status |
Condition |
LED1 |
Green |
On |
Network connection established |
LED1 |
Green |
Off |
Network connection is not established |
LED2 |
Yellow |
On |
Collision has occurred |
LED2 |
Yellow |
Off |
Collision has not occurred |
LED3 |
Green |
Blinking |
Data is being received |
LED3 |
Green |
Off |
Data is not being received |
LED4 |
Green |
On |
Data is being transmitted |
LED4 |
Green |
Off |
Data is not being transmitted |
LED5 |
Yellow |
On |
Polarity error |
LED5 |
Yellow |
Off |
No polarity error |
LED6 |
Yellow |
On |
SQE test feature enabled |
LED6 |
Yellow |
Off |
SQE test feature disabled |
LED7 |
Green |
On |
Power is on |
LED7 |
Green |
Off |
Power is off |
MISCELLANEOUS TECHNICAL NOTES |
The AUI port should be directly connected to the workstation. If you cannot connect to the workstation, an AUI drop cable (which cannot exceed 3 feet in length) may be used. |