EDIMAX COMPUTER COMPANY
1000T
NIC Type |
Ethernet |
Transfer Rate |
10Mbps |
Data Bus |
8-bit ISA |
Topology |
Star |
Wiring Type |
Unshielded twisted pair AUI transceiver via DB-15 port |
Boot ROM |
Available |
CONNECTORS | |
Setting |
Jumper |
External power LED |
JP2 |
I/O BASE ADDRESS | ||||
Address |
JP1A |
JP1B |
JP1C | |
300h |
Closed |
Closed |
Closed | |
320h |
Closed |
Closed |
Open | |
340h |
Closed |
Open |
Closed | |
360h |
Closed |
Open |
Open |
INTERRUPT SETTINGS | ||||||
IRQ |
JP1D |
JP1E |
JP1F |
JP1G |
JP1H |
JP1I |
2 |
Closed |
Open |
Open |
Open |
Open |
Open |
3 |
Open |
Closed |
Open |
Open |
Open |
Open |
4 |
Open |
Open |
Closed |
Open |
Open |
Open |
5 |
Open |
Open |
Open |
Closed |
Open |
Open |
6 |
Open |
Open |
Open |
Open |
Closed |
Open |
7 |
Open |
Open |
Open |
Open |
Open |
Closed |
DMA CHANNEL | ||||
Channel |
JP1J |
JP1K |
JP1L |
JP1M |
DMA1 |
Closed |
Open |
Closed |
Open |
DMA3 |
Open |
Closed |
Open |
Closed |
BOOT ROM ADDRESS | |||||
Address |
JP3A |
JP3B |
JP3C |
JP3D | |
C0000h |
Closed |
Closed |
Closed |
Closed | |
C4000h |
Open |
Closed |
Closed |
Closed | |
C8000h |
Closed |
Open |
Closed |
Closed | |
CC000h |
Open |
Open |
Closed |
Closed | |
D0000h |
Closed |
Closed |
Open |
Closed | |
D4000h |
Open |
Closed |
Open |
Closed | |
D8000h |
Closed |
Open |
Open |
Closed | |
DC000h |
Open |
Open |
Open |
Closed |
CABLE TYPE | |||
Type |
JP4 |
JP10A-JP10F |
JP11 |
AUI transceiver via DB-15 port |
Pins 2 & 3 Closed |
Open |
Pins 1 & 2 Closed |
Shielded/Unshielded twisted pair |
Pins 2 & 3 Closed |
Closed |
Pins 2 & 3 Closed |
BOOT ROM | ||
Setting |
JP5 | |
Disabled |
Open | |
Enabled |
Closed |
AUTOPOLARITY | ||
Setting |
JP6 | |
Enabled |
Pins 1 & 2 Closed | |
Disabled |
Pins 2 & 3 Closed | |
Note: When disabled, if the wires' polarities are reversed, the card may be damaged. |
SQE (SIGNAL QUALITY ERROR) | ||
Setting |
JP7 | |
Enabled |
Pins 1 & 2 Closed | |
Disabled |
Pins 2 & 3 Closed | |
Note: Signal Quality Error (SQE), is an internal check of the collision circuitry and path. |
SEGMENT LENGTH | ||
Maximum Length |
JP8 | |
185 meters |
Pins 2 & 3 closed | |
300 meters |
Pins 1 & 2 closed | |
Note:Segment length is the total length of cable between the two farthest cards on the segment. Each card on the segment must have this option set the same. |
LINK INTEGRITY TEST | ||
Setting |
JP9 | |
Enabled |
Pins 1 & 2 Closed | |
Disabled |
Pins 2 & 3 Closed |
DIAGNOSTIC LED(S) | |||
LED |
Color |
Status |
Condition |
LED1 |
Yellow |
On |
A reversed twisted pair is detected and corrected |
LED2 |
Green |
On |
A properly functioning twisted pair is detected |