CORVUS SYSTEMS, INC.
TRANSPORTER MODEL 8010-10440
NIC Type |
OmniNet (proprietary) |
Network Transfer Rate |
Unidentified |
Data Bus |
8-bit ISA |
Topology |
Linear Bus |
Wire Type |
Shielded/Unshielded twisted pair |
Boot ROM |
Available |
CONNECTIONS | |
Function |
Label |
Unshielded or shielded twisted pair via 1/8" plug |
CN1 |
USER CONFIGURABLE SETTINGS | |||
Setting |
Label |
Position | |
Factory configured - do not alter |
E2 |
Pins 1 & 2 closed |
NODE ADDRESS | ||||||
Setting |
U14/1 |
U14/2 |
U14/3 |
U14/4 |
U14/5 |
U14/6 |
0 |
On |
On |
On |
On |
On |
On |
1 |
Off |
On |
On |
On |
On |
On |
2 |
On |
Off |
On |
On |
On |
On |
3 |
Off |
Off |
On |
On |
On |
On |
4 |
On |
On |
Off |
On |
On |
On |
59 |
Off |
Off |
On |
Off |
Off |
Off |
60 |
On |
On |
Off |
Off |
Off |
Off |
61 |
Off |
On |
Off |
Off |
Off |
Off |
62 |
On |
Off |
Off |
Off |
Off |
Off |
63 |
Off |
Off |
Off |
Off |
Off |
Off |
Note: A total of 64 node address settings are available. The switches are a binary representation of the decimal node addresses. U14/6 is the Most Significant Bit and switch U14/1 is the Least Significant Bit. The switches have the following decimal values: U14/6=32, U14/5=16, U14/4=8, U14/3=4, U14/2=2, U14/1=1. Turn off the switches and add the values of the switches that are off to obtain the correct node ID. (Off=1, On=0) |
BIAS SELECTION | ||
Setting |
U14/7 |
U14/8 |
Normal |
Off |
Off |
Biased |
On |
On |
Note:Only one machine per network should be set to biased. |
BASE I/O ADDRESS | |||||
Setting |
E1/A |
E1/B |
E1/C |
E1/D | |
240h |
Closed |
Open |
Open |
Open | |
248h |
Open |
Closed |
Open |
Open | |
250h |
Open |
Open |
Closed |
Open | |
258h |
Open |
Open |
Open |
Closed | |
Note:E1 is a set of solder contacts. To change the address, you must cut the trace on E1/C andhard-wire a jumper with a soldering gun. |