COMPU-SHACK PRODUCTION, GMBH
CS-FDDI ISA-MMF-SAS
Card Type |
Network Interface Card |
NIC Type |
FDDI |
Maximum Onboard Memory |
Unidentified |
Boot ROM |
Available |
Network Transfer Rate |
100Mbps |
Topology |
Ring |
Wiring Type |
Fiber optic cable |
Data Bus |
16-bit ISA |
CONNECTIONS | |
Function |
Label |
Fiber-optic connector via MIC |
CN1 |
USER CONFIGURABLE SETTINGS | |||
Function |
Label |
Position | |
Boot ROM disabled |
JP13/A |
Open | |
Boot ROM enabled |
JP13/A |
Closed | |
Factory configured - do not alter |
JP13/E |
Unidentified | |
Factory configured - do not alter |
JP21/pins 1 & 2 |
Unidentified | |
Hard configuration mode selected |
JP21/pins 3 & 4 |
Open | |
Soft configuration mode selected |
JP21/pins 3 & 4 |
Closed |
BASE I/O ADDRESS SELECTION | ||||
Address |
JP13/B |
JP13/C |
JP13/D | |
200h-21Fh |
Closed |
Closed |
Closed | |
220h-23Fh |
Closed |
Closed |
Open | |
240h-25Fh |
Closed |
Open |
Closed | |
280h-29Fh |
Closed |
Open |
Open | |
300h-31Fh |
Open |
Closed |
Closed | |
320h-33Fh |
Open |
Closed |
Open | |
340h-35Fh |
Open |
Open |
Closed |
INTERRUPT SELECTION | |||||||||||
IRQ |
JP2/A |
JP2/B |
JP2/C |
JP2/D |
JP2/E |
JP2/F |
JP2/G |
JP2/H |
JP2/I |
JP2/J | |
3 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed | |
4 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open | |
5 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open | |
7 |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open | |
9 |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open | |
10 |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open | |
11 |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open | |
12 |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open | |
14 |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open | |
15 |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
DIAGNOSTIC LED(S) | |||
LED |
Color |
Status |
Condition |
LED1 |
Unidentified |
On |
See conditions in note below |
LED1 |
Unidentified |
Off |
See conditions in note below |
LED2 |
Red |
On |
Cable fault (SDDI only) |
LED2 |
Red |
Off |
Cable active |
LED3 |
Yellow |
On |
Data is being transmitted/received |
LED3 |
Yellow |
Off |
Data is not being transmitted/received |
LED4 |
Green |
On |
Ring connection is good |
LED4 |
Green |
Off |
Ring connection is broken |
TECHNICAL NOTE |
Note: When the board is operated in soft configuration mode, jumpers JP13 and JP2 must be open. JP21/pins 1 & 2 function to toggle I/O address selection. If an I/O address collision is detected during installation, the shunt on JP21/pins 1 & 2 can be changed (while the PC is running) to force the software to try the next larger I/O address. For example, if a collision is detected using I/O address 300h, removing shunt on JP21/pins 1 & 2 will force the software to try I/O address 320h. |