COMPU-SHACK PRODUCTION, GMBH
CS-ARCNET-KARTE (REV. 3.31/3.31S)
NIC Type: |
ARCnet |
Transfer Rate: |
2.5Mbps |
Data Bus: |
8-bit ISA |
Topology: |
Linear Bus |
Wiring Type |
RG62A/U 93ohm coaxial |
Boot ROM |
Available |
INTERRUPT SELECT - J2 | ||||||
IRQ |
Jumper A |
Jumper B |
Jumper D |
Jumper D |
Jumper E | |
IRQ2 |
Closed |
Open |
Open |
Open |
Open | |
IRQ3 |
Open |
Closed |
Open |
Open |
Open | |
IRQ4 |
Open |
Open |
Closed |
Open |
Open | |
IRQ5 |
Open |
Open |
Open |
Closed |
Open | |
IRQ7 |
Open |
Open |
Open |
Open |
Closed |
RESPONSE TIME-OUTS | |||
Response Time |
J4/jumper A |
J4/jumper B | |
74.7s |
Open |
Open | |
283.4s |
Closed |
Open | |
561.8s |
Open |
Closed | |
1118.6s |
Closed |
Closed |
I/O ADDRESS | ||||||
Address |
S1/1 |
S1/2 |
S1/3 |
S1/4 |
S1/5 |
S1/6 |
2E0h |
Off |
On |
Off |
Off |
Off |
On |
200h |
Off |
On |
On |
On |
On |
On |
210h |
Off |
On |
On |
On |
On |
Off |
220h |
Off |
On |
On |
On |
Off |
On |
I/O ADDRESS | ||||||
Address |
S1/1 |
S1/2 |
S1/3 |
S1/4 |
S1/5 |
S1/6 |
230h |
Off |
On |
On |
On |
Off |
Off |
240h |
Off |
On |
On |
Off |
On |
On |
250h |
Off |
On |
On |
Off |
On |
Off |
260h |
Off |
On |
On |
Off |
Off |
On |
270h |
Off |
On |
On |
Off |
Off |
Off |
280h |
Off |
On |
Off |
On |
On |
On |
290h |
Off |
On |
Off |
On |
On |
Off |
2A0h |
Off |
On |
Off |
On |
Off |
On |
2B0h |
Off |
On |
Off |
On |
Off |
Off |
2C0h |
Off |
On |
Off |
Off |
On |
On |
2D0h |
Off |
On |
Off |
Off |
On |
Off |
2F0h |
Off |
On |
Off |
Off |
Off |
Off |
300h |
Off |
Off |
On |
On |
On |
On |
310h |
Off |
Off |
On |
On |
On |
Off |
320h |
Off |
Off |
On |
On |
Off |
On |
330h |
Off |
Off |
On |
On |
Off |
Off |
340h |
Off |
Off |
On |
Off |
On |
On |
350h |
Off |
Off |
On |
Off |
On |
Off |
360h |
Off |
Off |
On |
Off |
Off |
On |
370h |
Off |
Off |
On |
Off |
Off |
Off |
380h |
Off |
Off |
Off |
On |
On |
On |
390h |
Off |
Off |
Off |
On |
On |
Off |
3A0h |
Off |
Off |
Off |
On |
Off |
On |
3B0h |
Off |
Off |
Off |
On |
Off |
Off |
3C0h |
Off |
Off |
Off |
Off |
On |
On |
3D0h |
Off |
Off |
Off |
Off |
On |
Off |
3E0h |
Off |
Off |
Off |
Off |
Off |
On |
3F0h |
Off |
Off |
Off |
Off |
Off |
Off |
MEMORY ADDRESS | ||||
Address |
S1/7 |
S1/8 |
S1/9 |
S1/10 |
C0000h |
Off |
Off |
On |
On |
D0000h |
Off |
Off |
On |
Off |
E0000h |
Off |
Off |
Off |
On |
NODE ID NUMBER | ||||||||
ID # |
S2/1 |
S2/2 |
S2/3 |
S2/4 |
S2/5 |
S2/6 |
S2/7 |
S2/8 |
1 |
On |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
255 |
On |
On |
On |
On |
On |
On |
On |
On |
Note:Nodes can be numbered from 1 to 255. The switches are a binary representation of the node numbers. When a switch is on, the corresponding bit is set to 1 and has the following decimal value: S2/1=1, S2/2=2, S2/3=4, S2/4=8, S2/5=16, S2/6=32, S2/7=64, S2/8=128. |
DIAGNOSTIC LED | |
Status |
Condition |
On |
Data is being transmitted or received |
Off |
Data is not being transmitted or received |