COMPEX, INC.
ENET16-COMBO/P
NIC Type |
Ethernet |
Transfer Rate |
10Mbps |
Data Bus |
16-bit ISA |
Topology |
Linear bus/Star |
Wiring Type |
Shielded/Unshielded Twisted Pair RG-58A/U 50ohm coaxial AUI transceiver via DB-15 port |
Boot ROM |
Available |
SEGMENT LENGTH | ||
Maximum Length |
J1 | |
185 meters |
Closed | |
300 meters |
Open | |
Note:Segment length is the total length of cable between the two farthest cards on the segment. Each card on the segment must have this option set the same. |
NETWORK VERSION | ||
Version |
J2 | |
Ethernet version 2 |
Open | |
Ethernet version 1 |
Closed |
LINK INTEGRITY TEST | ||
Setting |
J3 | |
Enabled |
Pins 1 & 2 closed | |
Disabled |
Pins 2 & 3 closed |
I/O BASE ADDRESS | ||||
Address |
J5A |
J5B |
J5C |
J5D |
200h |
Closed |
Closed |
Closed |
Closed |
240h |
Closed |
Closed |
Open |
Closed |
280h |
Closed |
Open |
Closed |
Closed |
2C0h |
Closed |
Open |
Open |
Closed |
300h |
Open |
Closed |
Closed |
Closed |
340h |
Open |
Closed |
Open |
Closed |
380h |
Open |
Open |
Closed |
Closed |
3C0h |
Open |
Open |
Open |
Closed |
INTERRUPT REQUEST | ||
IRQ |
J4A |
J4B |
4 |
Closed |
Open |
5 |
Closed |
Closed |
7 |
Open |
Closed |
DIAGNOSTIC LED(S) | ||
LED |
Status |
Condition |
LED1 |
On |
Twisted Pair link is correctly configured |
LED1 |
Off |
Twisted Pair link is incorrectly configured |
LJ1 |
On |
Data is being transmitted or received |
LJ1 |
Off |
Data is not being transmitted or received |