DANPEX CORPORATION
EN-9000
NIC Type |
Ethernet |
Transfer Rate |
10Mbps |
Data Bus |
32-bit EISA |
Topology |
Star Linear Bus |
Wiring Type |
RG58A/U 50ohm coaxial Shielded/Unshielded twisted pair AUI transceiver via DB-15 port |
Boot ROM |
Available |
ACTIVITY LED ENABLE | ||
Setting |
JP1 | |
Disabled |
Pins 1 & 2 closed | |
Enabled |
Pins 2 & 3 closed | |
Note:If the network hub has an activity LED for each line, setting this option to enabled will allow the hub LED to operate properly |
CABLE TYPE | ||
Type |
JP6 | |
Software select |
Pins 1 & 2 closed | |
RG58A/U 50ohm coaxial |
Pins 2 & 3 closed |
ONBOARD TERMINATOR | ||
Setting |
JP7 | |
Disabled |
Pins 2 & 3 closed | |
Enabled |
Pins 1 & 2 closed | |
Note:When using RG58A/U 50ohm coaxial cable the onboard 50ohm terminator may be used instead of using a T-connector and an external terminator. |
DIAGNOSTIC LED(S) | ||
LED |
Status |
Condition |
LED1 |
On |
Data is being transmitted |
LED1 |
Off |
Data is not being transmitted |
LED2 |
On |
Twisted pair connection is good |
LED2 |
Off |
Twisted pair connection is broken |
LED3 |
On |
Data is being received |
LED3 |
Off |
Data is not being received |
LED4 |
On |
Collision detected on network |
LED4 |
Off |
No collisions detected on network |
FACTORY CONFIGURED SETTINGS | |
Jumper |
Setting |
JP2 |
Unused |
JP3 |
Unused |
JP4 |
Unused |
JP5 |
Unused |