DANPEX CORPORATION (ADI SYSTEMS, INC.)
AQUILA AQ-1000CX
NIC Type |
Ethernet |
Transfer Rate |
10Mbps |
Data Bus |
8-bit ISA |
Topology |
Linear Bus |
Wiring Type |
RG-58A/U 50ohm coaxial AUI Transceiver via DB-15 port |
Boot ROM |
Available |
BOOT ROM ADDRESS | |||
Address |
JP1A |
JP1B | |
C8000-CBFFFh |
Open |
Open | |
CC000-CFFFFh |
Closed |
Open | |
D0000-D3FFFh |
Open |
Closed | |
D4000-D7FFFh |
Closed |
Closed |
I/O BASE ADDRESS | |||
Address |
JP1C |
JP1D | |
300-31Fh |
Open |
Open | |
320-33Fh |
Closed |
Open | |
340-35Fh |
Open |
Closed | |
360-37Fh |
Closed |
Closed |
INTERRUPT REQUEST | ||||||
IRQ |
JP2A |
JP2B |
JP2C |
JP2D |
JP2E | |
2 |
Closed |
Open |
Open |
Open |
Open | |
3 |
Open |
Closed |
Open |
Open |
Open | |
4 |
Open |
Open |
Closed |
Open |
Open | |
5 |
Open |
Open |
Open |
Closed |
Open | |
7 |
Open |
Open |
Open |
Open |
Closed |
CABLE TYPE | |||
Type |
JP3 |
JP4A - JP4F | |
RG-58A/U 50ohm coaxial |
Open |
Pins 2 & 3 Closed | |
AUI transceiver via DB-15 port |
Open |
Pins 1 & 2 Closed |
DIAGNOSTIC LED(S) | |||
LED |
Color |
Status |
Condition |
LED1 |
Green |
On |
Data is being transmitted or received |
LED1 |
Green |
Off |
Data is not being transmitted or received |