ALLIED TELESYN, INC.
AT-270
Card Type |
Single Port Transceiver |
NIC Type |
Ethernet |
Network Transfer Rate |
10Mbps/CSMA/CD |
Topology |
Linear Bus |
Wiring Type |
AUI transceiver via DB-15 port |
Data Bus |
None |
CONNECTIONS | |||
Function |
Label |
Function |
Label |
AUI transceiver via DB-15 |
CN1 |
BNC connector |
CN3 |
AUI transceiver via DB-15 |
CN2 |
USER CONFIGURABLE SETTINGS | |||
Function |
Label |
Position | |
SQE/Heartbeat switch disabled |
SW1 |
0 | |
SQE/Heartbeat switch enabled |
SW1 |
1 |
DIAGNOSTIC LED(S) | |||
LED |
Color |
Status |
Condition |
Power 1 |
Unidentified |
On |
Power for port 1 is present |
Power 1 |
Unidentified |
Off |
Power for port 1 is absent |
Power 2 |
Unidentified |
On |
Power for port 2 is present |
Power 2 |
Unidentified |
Off |
Power for port 2 is absent |
TRANSMIT |
Unidentified |
On |
Data is being transmitted |
TRAMSMIT |
Unidentified |
Off |
Data is not being transmitted |
RECEIVE |
Unidentified |
On |
Data is being received |
RECEIVE |
Unidentified |
Off |
Data is not being received |
COLLISION |
Unidentified |
On |
Collision detected on network |
COLLSION |
Unidentified |
Off |
No collision detected on network |
SQE TEST |
Unidentified |
On |
SQE is enabled |
SQE TEST |
Unidentified |
Off |
SQE is disabled |