IPTool.net.ua IPTools.net.ua

ARCTALK NB

ACTINET SYSTEMS, INC.

ARCTALK NB

NIC Type

ARCnet

Transfer Rate

2.5Mbps

Data Bus

32-bit NuBus

Topology

Star

Wiring Type

RG62/U 93ohm coaxial

Boot ROM

Available

SEGMENT LENGTH AND RESPONSE/RECONFIGURATION TIMEOUTS

Maximum Length

Response Time

Reconfig. Time

ET1

ET2

22,000 feet

74.7s

840ms

Pins 1 & 2 closed

Pins 1 & 2 closed

96,000 feet

283.4s

1680ms

Pins 2 & 3 closed

Pins 1 & 2 closed

195,000 feet

561.8s

1680ms

Pins 1 & 2 closed

Pins 2 & 3 closed

393,000 feet

1118.6s

1680ms

Pins 2 & 3 closed

Pins 2 & 3 closed

Note: All NICs on the network segment must have this option set the same.

DIAGNOSTIC LED(S)

LED

Color

Status

Condition

LED1

Green

On

Normal operation

LED1

Green

Blinking

There is a break in the network (not necessarily at this card)

LED1

Green

Off

Fault detected

Note: If a fault is detected, it can be any one or a combination of the following: Card is not attached to an active network, the card is not selected in the control panel, AppleTalk is not enabled in the Chooser, the hybrid transceiver on the card may be defective, there are no active stations on the network, the Mac's -12VDC power supply is malfunctioning, the hub is defective, or there is a break in the network cable.