ACCTON TECHNOLOGY CORPORATION
Etherpair-NE2 (EN1622)
NIC Type |
Ethernet |
Transfer Rate |
10Mbps |
Data Bus |
16-bit MCA |
Topology |
Linear bus Star |
Wiring Type |
Unshielded twisted pair AUI transceiver via DB-15 port |
Boot ROM |
Available |
SIGNAL QUALITY ERROR (SQE) TEST |
||
Setting |
JP1 |
|
Disabled |
Closed |
|
|
Enabled |
Open |
Note: Signal Quality Error (SQE) is a test of the collision circuitry and path. |
LINK INTEGRITY TEST |
||
Setting |
JP2 |
|
Enabled |
Closed |
|
|
Disabled |
Open |
Note: Link Integrity is only used with 10Base-T wiring. When using an AUI transceiver, the test should be disabled. |
CABLE TYPE |
||
Type |
JP3A - JP3I |
|
Unshielded twisted pair |
Pins 1 & 2 Closed |
|
|
AUI transceiver via DB-15 port |
Pins 2 & 3 Closed |
DIAGNOSTIC LED(S) |
||||
Led |
Color |
Link Integrity |
Status |
Condition |
LED1 |
Red |
N/A |
Off |
No collisions detected on network |
LED1 |
Red |
N/A |
Blinking |
Collision detected on network |
LED2 |
Green |
N/A |
On |
Data is being received power |
LED2 |
Green |
N/A |
Blinking |
Data is being transmitted |
LED3 |
Red |
N/A |
Off |
Normal operational |
LED3 |
Red |
N/A |
On |
Card is jabbering, transmitting continuously |
LED4 |
Green |
Enabled |
On |
Twisted pair network connection is good |
LED4 |
Green |
Enabled |
Off |
Twisted pair network connection is broken |
LED4 |
Green |
Enabled |
Blinking |
Data is being received |
LED4 |
Green |
Disabled |
On |
Data is being received power |
LED4 |
Green |
Disabled |
Off |
Data is not being received power |
LED4 |
Green |
Disabled |
Blinking |
Data is being received |