COMPAQ COMPUTER CORPORATION
PROLIANT 2000R
Processor |
Pentium |
Processor Speed |
66/90MHz |
Chip Set |
Unidentified |
Video Chip Set |
None |
Maximum Onboard Memory |
512MB (EDO supported) |
Maximum Video Memory |
1MB |
Cache |
256/512KB |
BIOS |
Unidentified |
Dimensions |
305mm x 244mm |
I/O Options |
Unidentified |
NPU Options |
None |
CONNECTIONS | |||
Purpose |
Location |
Purpose |
Location |
Proprietary slots |
SL1 SL4 |
External memory card |
SL5 |
Note: The location and types of I/O options are unidentified. |
USER CONFIGURABLE SETTINGS | |||
Function |
Label |
Position | |
|
Factory configured - do not alter |
SW4/1 |
On |
|
Soft switching mode enabled |
SW4/2 |
On |
Soft switching mode disabled |
SW4/2 |
Off | |
|
Keyboard broadcasting mode disabled |
SW4/3 |
Off |
Keyboard broadcasting mode enabled |
SW4/3 |
On | |
|
Mouse broadcasting mode disabled |
SW4/4 |
Off |
Mouse broadcasting mode enabled |
SW4/4 |
On | |
|
Scan mode enabled |
SW4/5 |
On |
Scan mode disabled |
SW4/5 |
Off | |
|
Tiering mode disabled |
SW4/6 |
Off |
Tiering mode enabled |
SW4/6 |
On | |
|
Factory configured - do not alter |
SW4/7 |
Unidentified |
|
Factory configured - do not alter |
SW4/8 |
Unidentified |
DRAM CONFIGURATION | ||||
Size |
Bank 0 |
Bank 1 |
Bank 2 |
Bank 3 |
64MB |
(4) 4M x 36 |
None |
None |
None |
128MB |
(4) 8M x 36 |
None |
None |
None |
256MB |
(4) 16M x 36 |
None |
None |
None |
128MB |
(4) 4M x 36 |
(4) 4M x 36 |
None |
None |
256MB |
(4) 8M x 36 |
(4) 8M x 36 |
None |
None |
256MB |
(4) 4M x 36 |
(4) 4M x 36 |
(4) 4M x 36 |
(4) 4M x 36 |
512MB |
(4) 8M x 36 |
(4) 8M x 36 |
(4) 8M x 36 |
(4) 8M x 36 |
Note: The location of banks 0 & 1 is unidentified. Banks 2 & 3 are located on the memory card. |
CACHE CONFIGURATION |
Note: The location of the cache is unidentified. |
MONITOR SELECTION NOTE |
Note: The Proliant 2000R is capable of controlling up to 8 servers, each with their own monitor. To select a monitor type for a specific server, first consult either the 4 or 8 Port Monitor Control Selection Table to determine which switches are used for the configuration.. Then refer to the Server Monitor Selection table to determine the individual switch settings. |
4 PORT MONITOR CONTROL SELECTION | ||
Switch |
Controlling switches |
Server controlled |
S1 |
S1/1 - 4 |
1 |
S1 |
S1/5 - 8 |
2 |
S2 |
S2/1 - 4 |
3 |
S2 |
S2/5 - 8 |
4 |
8 PORT MONITOR CONTROL SELECTION | ||
Switch |
Controlling switches |
Server controlled |
S1 |
S1/1 - 4 |
1 |
S1 |
S1/5 - 8 |
2 |
S2 |
S2/1 - 4 |
3 |
S2 |
S2/5 - 8 |
4 |
S3 |
S3/1 - 4 |
5 |
S3 |
S3/5 - 8 |
6 |
S4 |
S3/1 - 4 |
7 |
S4 |
S3/5 - 8 |
8 |
SERVER MONITOR SELECTION | ||||
Type |
SW1/1 orSW1/5 |
SW1/2 orSW1/6 |
SW1/3 orSW1/7 |
SW1/4 orSW1/8 |
VGA |
Off |
Off |
On |
Off |
Monochrome |
Off |
Off |
On |
Off |
VGA |
Off |
On |
Off |
Off |
SVGA |
Off |
On |
Off |
Off |
SVGA- Compaq 430 |
On |
On |
Off |
On |
XVGA IBM8512 |
Off |
On |
Off |
Off |
XVGA IBM8513 |
Off |
On |
Off |
Off |
XVGA IBM8514 |
On |
On |
Off |
Off |
XVGA IBM8515 |
On |
Off |
Off |
Off |
Note: Each bank of switches must reflect the type of monitor configured on the server. |