IPTool.net.ua IPTools.net.ua

PROLIANT 2000R

COMPAQ COMPUTER CORPORATION

PROLIANT 2000R

Processor

Pentium

Processor Speed

66/90MHz

Chip Set

Unidentified

Video Chip Set

None

Maximum Onboard Memory

512MB (EDO supported)

Maximum Video Memory

1MB

Cache

256/512KB

BIOS

Unidentified

Dimensions

305mm x 244mm

I/O Options

Unidentified

NPU Options

None

CONNECTIONS

Purpose

Location

Purpose

Location

Proprietary slots

SL1 SL4

External memory card

SL5

Note: The location and types of I/O options are unidentified.

USER CONFIGURABLE SETTINGS

Function

Label

Position

Factory configured - do not alter

SW4/1

On

Soft switching mode enabled

SW4/2

On

 

Soft switching mode disabled

SW4/2

Off

Keyboard broadcasting mode disabled

SW4/3

Off

 

Keyboard broadcasting mode enabled

SW4/3

On

Mouse broadcasting mode disabled

SW4/4

Off

 

Mouse broadcasting mode enabled

SW4/4

On

Scan mode enabled

SW4/5

On

 

Scan mode disabled

SW4/5

Off

Tiering mode disabled

SW4/6

Off

 

Tiering mode enabled

SW4/6

On

Factory configured - do not alter

SW4/7

Unidentified

Factory configured - do not alter

SW4/8

Unidentified

DRAM CONFIGURATION

Size

Bank 0

Bank 1

Bank 2

Bank 3

64MB

(4) 4M x 36

None

None

None

128MB

(4) 8M x 36

None

None

None

256MB

(4) 16M x 36

None

None

None

128MB

(4) 4M x 36

(4) 4M x 36

None

None

256MB

(4) 8M x 36

(4) 8M x 36

None

None

256MB

(4) 4M x 36

(4) 4M x 36

(4) 4M x 36

(4) 4M x 36

512MB

(4) 8M x 36

(4) 8M x 36

(4) 8M x 36

(4) 8M x 36

Note: The location of banks 0 & 1 is unidentified. Banks 2 & 3 are located on the memory card.

CACHE CONFIGURATION

Note: The location of the cache is unidentified.

MONITOR SELECTION NOTE

Note: The Proliant 2000R is capable of controlling up to 8 servers, each with their own monitor. To select a monitor type for a specific server, first consult either the 4 or 8 Port Monitor Control Selection Table to determine which switches are used for the configuration.. Then refer to the Server Monitor Selection table to determine the individual switch settings.

4 PORT MONITOR CONTROL SELECTION

Switch

Controlling switches

Server controlled

S1

S1/1 - 4

1

S1

S1/5 - 8

2

S2

S2/1 - 4

3

S2

S2/5 - 8

4

8 PORT MONITOR CONTROL SELECTION

Switch

Controlling switches

Server controlled

S1

S1/1 - 4

1

S1

S1/5 - 8

2

S2

S2/1 - 4

3

S2

S2/5 - 8

4

S3

S3/1 - 4

5

S3

S3/5 - 8

6

S4

S3/1 - 4

7

S4

S3/5 - 8

8

SERVER MONITOR SELECTION

Type

SW1/1 orSW1/5

SW1/2 orSW1/6

SW1/3 orSW1/7

SW1/4 orSW1/8

VGA

Off

Off

On

Off

Monochrome

Off

Off

On

Off

VGA

Off

On

Off

Off

SVGA

Off

On

Off

Off

SVGA- Compaq 430

On

On

Off

On

XVGA IBM8512

Off

On

Off

Off

XVGA IBM8513

Off

On

Off

Off

XVGA IBM8514

On

On

Off

Off

XVGA IBM8515

On

Off

Off

Off

Note: Each bank of switches must reflect the type of monitor configured on the server.