IPTool.net.ua IPTools.net.ua

RAM 3000 DELUXE

EVEREX SYSTEMS, INC.

RAM 3000 DELUXE

Card Type

Memory Card

Chipset Controller

Unidentified

I/O Options

N/A

Maximum Dram

3072KB

DRAM CONFIGURATION

Size

Bank 0

Bank 1

Bank 2

Bank 3

Bank 4

Bank 5

512KB

(18) 256K x 1

NONE

NONE

NONE

NONE

NONE

1024KB

(18) 256K x 1

(18) 256K x 1

NONE

NONE

NONE

NONE

1536KB

(18) 256K x 1

(18) 256K x 1

(18) 256K x 1

NONE

NONE

NONE

2048KB

(18) 256K x 1

(18) 256K x 1

(18) 256K x 1

(18) 256K x 1

NONE

NONE

2560KB

(18) 256K x 1

(18) 256K x 1

(18) 256K x 1

(18) 256K x 1

(18) 256K x 1

NONE

3072KB

(18) 256K x 1

(18) 256K x 1

(18) 256K x 1

(18) 256K x 1

(18) 256K x 1

(18) 256K x 1

MEMORY SPEED SELECT

Setting

JP1

120 nano sec

Open

 

150 nano sec

Closed

PARITY CHECK SELECT

Setting

JP2

Enabled

Closed

Disabled

Open

STARTING ADDRESS/SIZE SELECT

Address

SW1/1

SW1/2

SW1/3

SW1/4

SW1/6

SW1/7

SW1/8

SW1/9

 

208h

On

On

On

On

On

On

On

On

 

218h

On

On

On

Off

On

On

On

Off

258h

On

Off

On

Off

On

Off

On

Off

268h

On

Off

Off

On

On

Off

Off

On

 

2A8h

Off

On

Off

On

Off

On

Off

On

 

2B8h

Off

On

Off

Off

Off

On

Off

Off

 

2E8h

Off

Off

Off

On

Off

Off

Off

On

Note: 258h is the default setting for EMS I/O port 1

268h is the default setting for EMS I/O port 2

MISCELLANEOUS TECHNICAL NOTE

If you are installing are installing two RAM 3000 Deluxe cards then you can not select 258h or 268h as EMS port addresses on the second card.

EMS I/O PORT 1 SELECT

Setting

SW1/5

Enabled

Off

Disabled

On

Note: If EMS port 1 is enabled then the EMS memory is 128KB-2048KB

EMS I/O PORT 2 SELECT

Setting

SW1/10

Enabled

Off

Disabled

On

Note: If EMS port 1 & 2 are enabled then the EMS memory is 2049KB-3072KB

INSTALLED MEMORY BANKS SELECT

Banks

SW2/1

SW2/2

SW2/3

0

Off

Off

Off

1

Off

Off

On

2

Off

On

Off

3

Off

On

On

4

On

Off

Off

5

On

Off

On

MEMORY BANK SELECT

Size

SW2/4

SW2/5

SW2/6

SW2/7

SW2/8

0KB

Off

Off

Off

Off

Off

512KB

Off

Off

On

Off

Off

1024KB

Off

On

Off

Off

Off

1536KB

Off

On

On

Off

Off

2048KB

On

Off

Off

Off

Off

2560KB

On

Off

On

Off

Off

3072KB

On

On

Off

Off

Off

STARTING ADDRESS/SIZE SELECT

Address

Size

SW3/2

SW3/3

SW3/4

SW3/5

SW3/6

SW3/7

SW3/8

00000h

0KB

Off

Off

Off

Off

Off

Off

Off

20000h

128KB

Off

Off

Off

Off

Off

Off

On

40000h

256KB

Off

Off

Off

Off

Off

On

Off

60000h

384KB

Off

Off

Off

Off

Off

On

On

80000h

512KB

Off

Off

Off

Off

On

Off

Off

A0000h

640KB

Off

Off

Off

Off

On

Off

On

10000h

1024KB

Off

Off

Off

On

Off

Off

Off

120000h

1152KB

Off

Off

Off

On

Off

Off

On

140000h

1280KB

Off

Off

Off

On

Off

On

Off

160000h

1408KB

Off

Off

Off

On

Off

On

On

180000h

1536KB

Off

Off

Off

On

On

Off

Off

1A0000h

1664KB

Off

Off

Off

On

On

Off

On

1C0000h

1792KB

Off

Off

Off

On

On

On

Off

1E0000h

1920KB

Off

Off

Off

On

On

On

On

200000h

2048KB

Off

Off

On

Off

Off

Off

Off

220000h

2176KB

Off

Off

On

Off

Off

Off

On

240000h

2304KB

Off

Off

On

Off

Off

On

Off

260000h

2432KB

Off

Off

On

Off

Off

On

On

280000h

2560KB

Off

Off

On

Off

On

Off

Off

2A0000h

2688KB

Off

Off

On

Off

On

Off

On

2C0000h

2816KB

Off

Off

On

Off

On

On

Off

2E0000h

2944KB

Off

Off

On

Off

On

On

On

300000h

3072KB

Off

Off

On

On

Off

Off

Off

EMS BUS SIZE SELECT

Setting

SW3/1

8-bit

Closed

16-bit

Open