AMERICAN POWER AND CONVERSION CORPORATION
APC INTERFACE #AP9500
Card Type |
UPS monitor |
Chipset Controller |
Unidentified |
I/O Options |
UPS control ports (2) |
Maximum DRAM |
N/A |
CONNECTIONS | |||
Purpose |
Location |
Purpose |
Location |
Novell/PowerChute mouse port |
J1 |
Novell 1/8" jack |
J2 |
ADDRESS SELECTION | ||
Address |
SW1/1 | |
231h |
Off | |
240h |
On |
LOW BATTERY SIGNAL CONFIGURATION | ||
Mode |
SW1/2 | |
APCC brand UPS |
Off | |
All other brands |
Unidentified | |
Note: If using a different brand of UPS, call the manufacturer to determine this setting. |
UPS SHUTDOWN CONFIGURATION | ||
Mode |
SW1/3 | |
Disabled |
Off | |
Enabled |
On | |
Note: This setting should be enabled only when using the mouse port configured with PowerChute for Novell. |
CONNECTOR SELECTION | |
Type |
SW1/4 |
1/8" jack |
Off |
Mouse port |
On |