SCIENTIFIC MICRO SYSTEMS, INC.
OMTI 7250
| |
Data bus: |
50-pin SCSI interface |
Size: |
5.75" x 8" |
Hard drive supported: |
Up to two ST506/412 MFM drives, up to two ST506/412 RLL 2,7 drives, up to two ESDI drives |
Floppy drives supported: |
Two 360KB, 720KB, 1.2MB, 1.44MB drives or 8" |
CONNECTIONS | |
Function |
Location |
50-pin SCSI interface |
J1 |
34-pin ESDI or MFM disk control connector |
J2 |
20-pin data cable connector |
J3 |
20-pin data cable connector |
J4 |
34-pin floppy drive connector |
J7 |
DC power connector |
J10 |
SCSI ADDRESS | ||||
SCSI ID |
W1 |
W2 |
W3 | |
0 |
open |
open |
open | |
1 |
closed |
open |
open | |
2 |
open |
closed |
open | |
3 |
closed |
closed |
open | |
4 |
open |
open |
closed | |
5 |
closed |
open |
closed | |
6 |
open |
closed |
close | |
7 |
closed |
closed |
closed |
USER CONFIGURABLE SETTINGS | |||
Function |
Location |
Setting | |
SCSI parity enabled |
W4 |
closed | |
SCSI parity disabled |
W4 |
open | |
Factory configured - do not alter |
W5 |
open | |
ST506/412 interface for drive select 1 enabled |
W6 |
open | |
ESDI interface for drive select 1 enabled |
W6 |
closed | |
ST506/412 interface for drive select 2 enabled |
W7 |
open | |
ESDI interface for drive select 2 enabled |
W7 |
closed | |
TRMPWR supplied by board |
W14/pins 1 & 2 |
closed | |
TRMPWR supplied by SCSI bus |
W14/pins 2 & 3 |
closed | |
Ready signal from pin 2 to FDC 765 disabled |
W15 |
open | |
Ready signal from pin 2 to FDC 765 enabled |
W15 |
closed | |
Ready signal from pin 34 to FDC 765 disabled |
W16 |
open | |
Ready signal from pin 34 to FDC 765 enabled |
W16 |
closed | |
Ready override to FDC 765 disabled (Rev. B only) |
W17 |
open | |
Ready override to FDC 765 enabled (Rev. B only) |
W17 |
closed | |
Motor On signal delay enabled |
W18 |
open | |
Motor On signal enabled |
W18 |
closed | |
Factory configured - do not alter |
W37 |
open | |
Factory configured - do not alter |
W38 |
open | |
Factory configured - do not alter |
W39 |
open | |
Note: Drive select 1 & 2 refer to the drive select jumper setting on the drive itself and should be set to 1 & 2 respectively. The location of W39 is unidentified. |
LUN 0 DISK TYPE CONFIGURATION | |||
Drive Type |
W9 |
W10 | |
ST506/412 |
open |
open | |
ESDI |
closed |
open | |
Removable ST506/412 |
open |
closed | |
Flexible disk |
closed |
closed |
LUN 1 DISK TYPE CONFIGURATION | |||
Drive Type |
W12 |
W13 | |
ST506/412 |
open |
open | |
ESDI |
closed |
open | |
Removable ST506/412 |
open |
closed | |
Flexible disk |
closed |
closed |
LUN 0/1 FLEXIBLE DISK DATA RATE | |||
Data Rate |
W8(Lun 0) |
W11(Lun 1) | |
250 Kbit |
open |
open | |
500 Kbit |
closed |
closed | |
Note: These settings apply only when W9 & W10 are both closed. |
LUN 0/1 SECTOR TYPE CONFIGURATION | |||
Mode |
W8(Lun 0) |
W11(Lun 1) | |
Soft sector enabled |
open |
open | |
Hard sector enabled |
closed |
closed | |
Note: These settings apply only when drive type is set to ST506/412. |