STORAGE DIMENSIONS
SDC1602B, SDC1602F
| |
Data bus: |
16-bit, ISA |
Size: |
Three/quarter-length, full-height card |
Hard drive supported: |
Up to seven SCSI devices |
Floppy drives supported: |
Two 360KB, 720KB, 1.2MB, or 1.44MB drives |
CONNECTIONS | |
Function |
Location |
4-pin connector - Drive active LED |
CN1 |
34-pin control cable connector - floppy drive |
CN2 |
50-pin SCSI connector - internal |
CN3 |
50-pin SCSI connector - external |
CN4 |
SCSI ID | ||||
SCSI ID |
S1/switch 1 |
S1/switch 2 |
S1/switch 3 | |
0 |
off |
off |
off | |
1 |
on |
off |
off | |
2 |
off |
on |
off | |
3 |
on |
on |
off | |
4 |
off |
off |
on | |
5 |
on |
off |
on | |
6 |
off |
on |
on | |
7 |
on |
on |
on |
USER CONFIGURABLE SETTINGS | |||
Function |
Location |
Setting | |
SCSI parity check disabled |
S1/switch 4 |
off | |
SCSI parity check enabled |
S1/switch 4 |
on | |
1GB translation enabled (DOS compatible) |
S1/switch 5 |
on | |
1GB translation disabled (UNIX compatible) |
S1/switch 5 |
off | |
SCSI synchronous negotiation disabled |
S1/switch 6 |
on | |
SCSI synchronous negotiation enabled |
S1/switch 6 |
off | |
Floppy drive port address is 3F0-3F7h |
W14 |
open | |
Floppy drive port address is 370-377h |
W14 |
closed | |
Floppy drive enabled |
W15 & W16 |
closed | |
Floppy drive disabled |
W15 & W16 |
open | |
I/O Channel Ready signal disabled |
W17 |
pins 1 & 2 closed | |
I/O Channel Ready signal enabled |
W17 |
pins 2 & 3 closed |
DMA CHANNEL CONFIGURATION - S1 | |||
DMA Channel |
S1/switch 7 |
S1/switch 8 | |
5 |
on |
on | |
6 |
off |
on | |
7 |
on |
off | |
Disabled |
off |
off |
I/O PORT ADDRESS CONFIGURATION - S2 | ||||
Address |
S2/switch 1 |
S2/switch 2 |
S2/switch 3 | |
130-133h |
on |
off |
on | |
134-137h |
on |
off |
off | |
230-233h |
off |
on |
on | |
234-237h |
off |
on |
off | |
330-333h |
on |
on |
on | |
334-337h |
on |
on |
off |
BIOS ADDRESS - S2 | |||
Address |
S2/switch 4 |
S2/switch 5 | |
C800h |
off |
off | |
D800h |
off |
on | |
DC00h |
on |
on | |
Disabled |
on |
off |
INTERRUPT REQUEST CONFIGURATION - S2 | ||||
IRQ |
S2/switch 6 |
S2/switch 7 |
S2/switch 8 | |
9 |
on |
off |
on | |
10 |
off |
on |
on | |
11 |
on |
on |
on | |
12 |
off |
off |
on | |
14 |
on |
on |
off | |
15 |
off |
on |
off | |
Note: This IRQ setting must be the same as the IRQ setting configured on jumpers W3-W8. |
INTERRUPT REQUEST CONFIGURATION | |||||||
IRQ |
W3 |
W4 |
W5 |
W6 |
W7 |
W8 | |
9 |
open |
open |
open |
open |
open |
closed | |
10 |
open |
open |
open |
open |
closed |
open | |
11 |
open |
open |
open |
closed |
open |
open | |
12 |
open |
open |
closed |
open |
open |
open | |
14 |
open |
closed |
open |
open |
open |
open | |
15 |
closed |
open |
open |
open |
open |
open | |
Note: This IRQ setting must be the same as the IRQ setting configured on S2, switches 6-8. |
DMA TRANSFER SPEED | |||
Speed |
W11 |
W13 | |
5.0MB/sec |
open |
open | |
5.7MB/sec |
open |
closed | |
6.7MB/sec |
closed |
open | |
8.0MB/sec |
closed |
closed |