IPTool
        
    
    Інструменти для системного адміністратора та не тільки
Меню
INFORTREND TECHNOLOGY, INC.
IFT-3101
| 
 Card Type  | 
 Hard drive controller  | 
| 
 Processor  | 
 486  | 
| 
 Maximum On Board Memory  | 
 32MB  | 
| 
 Hard Drives Supported  | 
 Up to fourteen Fast Wide SCSI-2 devices  | 
| 
 Floppy Drives Supported  | 
 None  | 
| 
 Data Bus  | 
 N/A  | 
| 
 Card Size  | 
 3.5" form factor  | 
| 
 Raid Levels Supported  | 
 0,1,3,5  | 
| 
 LOWER BOARD OF BASE MODULE CONNECTIONS  | |||
| 
 Function  | 
 Location  | 
 Function  | 
 Location  | 
| 
 56-pin connector  | 
 CN1  | 
 68-pin SCSI connector channel 0 - external  | 
 J1  | 
| 
 56-pin connector  | 
 CN2  | ||
| 
 UPPER BOARD OF BASE MODULE CONNECTIONS  | |||
| 
 Function  | 
 Location  | 
 Function  | 
 Location  | 
| 
 50-pin connector  | 
 CN3  | 
 50-pin connector  | 
 CN6  | 
| 
 50-pin connector  | 
 CN4  | 
 68-pin SCSI Wide connector channel 1 - external  | 
 J2  | 
| 
 50-pin connector  | 
 CN5  | 
 9-pin serial port - fail over port  | 
 J3  | 
| 
 IFT-9051UWS CONNECTIONS  | |||
| 
 Function  | 
 Location  | 
 Function  | 
 Location  | 
| 
 50-pin connector  | 
 CN7  | 
 68-pin SCSI Wide Single-ended connector channel 2 - external  | 
 J4  | 
| 
 50-pin connector  | 
 CN8  | 
 9-pin serial port - external  | 
 J5  | 
| 
 DRAM CONFIGURATION  | |
| 
 Size  | 
 Bank 0  | 
| 
 4MB  | 
 (1) 1M x 36  | 
| 
 8MB  | 
 (1) 2M x 36  | 
| 
 16MB  | 
 (1) 4M x 36  | 
| 
 32MB  | 
 (1) 8M x 36  | 
| 
 Note:EDO RAM supported. DRAM with or without parity is supported, but DRAM with parity is recommended.  | |
| 
 DIAGNOSTIC LED(S) - NOT DIAGRAMMED  | |||
| 
 LED  | 
 Color  | 
 Status  | 
 Condition  | 
| 
 POWER  | 
 Unidentified  | 
 On  | 
 Power is on  | 
| 
 POWER  | 
 Unidentified  | 
 Off  | 
 Power is off  | 
| 
 BUSY  | 
 Unidentified  | 
 Off  | 
 No activity  | 
| 
 BUSY  | 
 Unidentified  | 
 Blinking  | 
 Data is being accessed  | 
| 
 BUSY  | 
 Unidentified  | 
 On  | 
 Unprocessed cached data is still in memory  | 
| 
 ATTEN  | 
 Unidentified  | 
 On  | 
 Fault condition - a drive has failed  | 
| 
 ATTEN  | 
 Unidentified  | 
 Off  | 
 All drives are operating  | 
| 
 Note:The LEDs are located on front panel.  | |||
| 
 MISCELLANEOUS TECHNICAL NOTES  | 
| 
 The IFT-3101 is a Wide-SCSI to Wide-SCSI RAID controller which provides RAID 0, 1, 3 or 5 independently of the host systems operating system. The controller also comes with Ultra Wide differential upgrade board (IFT-9051UWD) - diagram not available.  |