INFORTREND TECHNOLOGY, INC.
IFT-2000A
| |
Data bus: |
32-bit PCI |
Size: |
Three-quarter length, full-height card |
Hard drive supported: |
Up to seven Fast SCSI-2 devices |
Floppy drives supported: |
None |
CONNECTIONS | |
Function |
Location |
4-pin connector - drive active LED |
JP2 |
50-pin SCSI connector - internal channel 0 |
JP4 |
50-pin SCSI connector - external channel 0 |
JP17 |
9-pin serial port - external |
JP20 |
USER CONFIGURABLE SETTINGS | |||
Function |
Location |
Setting | |
Factory configured - do not alter |
JP1 |
pins 1 & 2 closed | |
Factory configured - do not alter |
JP10 |
open | |
Factory configured - do not alter |
JP11 |
open | |
Factory configured - do not alter |
JP15 |
open |
ONBOARD CPU SELECTION | ||
CPU |
JP9 |
JP18 |
486SX-25 |
pins 1 & 2 closed |
pins 2 & 3 closed |
486DX-25 |
pins 1 & 2 closed |
pins 1 & 2, 3 & 4 closed |
486SX-33 |
pins 2 & 3 closed |
pins 2 & 3 closed |
486DX-33 |
pins 2 & 3 closed |
pins 1 & 2, 3 & 4 closed |
DRAM CONFIGURATIONS | |
Size |
Bank 0 |
2 MBytes |
(1) 512K x 36 |
4 MBytes |
(1) 1M x 36 |
8 MBytes |
(1) 2M x 36 |
16 MBytes |
(1) 4M x 36 |
32 MBytes |
(1) 8M x 36 |
Note: Minimum of 2 MBytes DRAM must be installed with/without parity function. Minimum of 4 MBytes DRAM suggested for RAID-3 and RAID-5 configurations. |
MISCELLANEOUS NOTES |
Pin 1 for jumpers JP1, JP9, JP18 are designated for diagram purposes only. |