CMD TECHNOLOGY, INC.
CRD-5400-001, CRD-5400-002, CRD-5400-003
Card Type |
Hard drive controller card |
Processor |
RISC |
Maximum Onboard Memory |
256MB DRAM |
Hard Drives supported |
Fourteen Fast SCSI devices (5400-001) Fourteen Fast/Wide SCSI devices (5400-002) Fourteen Fast/Wide SCSI devices (5400-003) |
Floppy drives supported |
None |
Data Bus |
Fast/Wide SCSI (5400-001) Fast/Wide SCSI (5400-002) Fast/Wide/Differential SCSI (5400-003) |
Form-factor |
5.25 inch |
RAID levels supported |
0, 1, 0+1, 4 and 5, JBOD |
CONNECTIONS | |||
Function |
Location |
Function |
Location |
50/68-pin SCSI connector - channel 1 |
CN1 |
UART/monitor connector |
CN7 |
50/68-pin SCSI connector - channel 0 |
CN2 |
Environmental control system - not used |
CN8 |
68-pin SCSI connector - host channel |
CN3 |
Battery connector |
CN9 |
External temperature sensor and UPS signals |
CN4 |
Power connector |
CN10 |
Alarm - external |
CN5 |
Fan power connector |
W8 |
Test connector |
CN6 |
|
|
Note: Connectors CN1 and CN2 differ on each model. See header. |
DRAM CONFIGURATION | ||
Size |
Bank 0 |
Bank 1 |
4MB |
(1) 1 x 36 |
None |
8MB |
(1) 1 x 36 |
(1) 1 x 36 |
8MB |
(1) 2 x 36 |
None |
16MB |
(1) 2 x 36 |
(1) 2 x 36 |
16MB |
(1) 4 x 36 |
None |
32MB |
(1) 4 x 36 |
(1) 4 x 36 |
32MB |
(1) 8 x 36 |
None |
64MB |
(1) 8 x 36 |
(1) 8 x 36 |
64MB |
(1) 16 x 36 |
None |
128MB |
(1) 16 x 36 |
(1) 16 x 36 |
128MB |
(1) 32 x 36 |
None |
256MB |
(1) 32 x 36 |
(1) 32 x 36 |
MISCELLANEOUS TECHNICAL NOTES |
To prevent power interruptions affecting data held in controllers cache, it is recommended that you connect an attached battery back-up or an uninterruptible power supply. Also, terminating drive buses by installing on-board resistors is not recommended because the end drive on the bus cannot be removed during a "hot swap" without leaving the bus unterminated. |