IPTool.net.ua IPTools.net.ua

CRD-5400-001, CRD-5400-002, CRD-5400-003

CMD TECHNOLOGY, INC.

CRD-5400-001, CRD-5400-002, CRD-5400-003

Card Type

Hard drive controller card

Processor

RISC

Maximum Onboard Memory

256MB DRAM

Hard Drives supported

Fourteen Fast SCSI devices (5400-001)

Fourteen Fast/Wide SCSI devices (5400-002)

Fourteen Fast/Wide SCSI devices (5400-003)

Floppy drives supported

None

Data Bus

Fast/Wide SCSI (5400-001)

Fast/Wide SCSI (5400-002)

Fast/Wide/Differential SCSI (5400-003)

Form-factor

5.25 inch

RAID levels supported

0, 1, 0+1, 4 and 5, JBOD

CONNECTIONS

Function

Location

Function

Location

50/68-pin SCSI connector - channel 1

CN1

UART/monitor connector

CN7

50/68-pin SCSI connector -

channel 0

CN2

Environmental control system - not used

CN8

68-pin SCSI connector - host channel

CN3

Battery connector

CN9

External temperature sensor and UPS signals

CN4

Power connector

CN10

Alarm - external

CN5

Fan power connector

W8

Test connector

CN6

 

 

Note: Connectors CN1 and CN2 differ on each model. See header.

DRAM CONFIGURATION

Size

Bank 0

Bank 1

4MB

(1) 1 x 36

None

8MB

(1) 1 x 36

(1) 1 x 36

8MB

(1) 2 x 36

None

16MB

(1) 2 x 36

(1) 2 x 36

16MB

(1) 4 x 36

None

32MB

(1) 4 x 36

(1) 4 x 36

32MB

(1) 8 x 36

None

64MB

(1) 8 x 36

(1) 8 x 36

64MB

(1) 16 x 36

None

128MB

(1) 16 x 36

(1) 16 x 36

128MB

(1) 32 x 36

None

256MB

(1) 32 x 36

(1) 32 x 36

MISCELLANEOUS TECHNICAL NOTES

To prevent power interruptions affecting data held in controllers cache, it is recommended that you connect an attached battery back-up or an uninterruptible power supply. Also, terminating drive buses by installing on-board resistors is not recommended because the end drive on the bus cannot be removed during a "hot swap" without leaving the bus unterminated.